• This card guide is in accordance to specification IEEE 1101.10. The required coding of the IEEE is integrated in the card guide head. With provision for the IEEE contact spring for groun ding of the alignmentpins of the PCB‘s front panel. Also with a provision for contacting a track near the PCB edge. This snap-in card guides can be secured with screws.
  • This card guide is also in accordance to specification IEEE 1101.10. For CompactPCI-power supplies and for Plug-in units fitted with SMD. With provision for the IEEE contact spring for grounding of the alignment pins of the PCB‘s front panel. Also with a provision for contacting a track near the PCB edge. This card guide is secured with screws.
  • This is an all purpose card guide with provision for a spring to contact front panels.
  • This is a length variable card guide constructed from 3 pieces. The center piece can be cut to any length. With a provision for a spring to contact front panels. These snap-in end pieces can also be secured with screws.
  • Lattice construction for heavy mechanical loads. With a provision for a spring to contact front panels and for contacting a track near the PCB edge. This card guides can be snapped in and/or secured with screws. Two versions: 1. With pressed-in nut M 2.5 for assembly to the horizontal rail with oval head screws M 2.5 x 12 2. Without a nut, but one can be added in the existing hexagonal molding.
  • The flange can be mounted to the side panel by means of the mounting screws for the horizontal rails. Material: aluminum, extruded Finish: anodized
  • Flange for Wall Mounting For mounting of a subrack on a wall. Material: aluminum Finish: blank, seawater resistant
  • This flange is suitable for mounting of a continous front panel of 85 HP and a hinged front panel of 85 HP in a subrack. The flange will be mounted to the side panel by means of the mounting screws for the horizontal rails. Material: aluminum, extruded Finish: colorless chromated
  • Flange without Nose This flange can be mounted at various depth on the side panel grid. Material: aluminum, extruded Finish: anodized
  • Material: aluminum Finish: anodized
  • Rear Cover F 84 HP For covering the wiring field of the subrack
  • Rear Cover RFI 84 HP Protective wiring rear cover for RFI shielded enclosure. Material: aluminum, 1 mm thick Finish: colorless chromated
  • Rear Cover RFI 84 HP, inside Protective wiring rear cover for RFI shielded enclosure. Material: aluminum, 1 mm thick Finish: colorless chromated
  • Rear Profile H22-RFI for screw on rear cover (type delta) For use with a rear cover. Material: aluminum Finish: colorless chromated
  • Side Panel Connector Join two subracks, one above the other. The side panel connector is mounted to the side panels by means of the mounting screws for the horizontal rails. (nom. depth 160 mm). Material: aluminum, 2 mm thick Finish: blank
  • Side Panel Extender Elongate a side panel about 60 mm to obtain a larger cabling space. The side panel extender is mounted to the side panel by means of the mounting screws for the horizontal rails. Material: aluminum, 2 mm thick Finish: colorless chromated
  • Side Panel Fi (flange integrated) The side panel and the flange are extruded in one piece. Material: aluminum, extruded Finish: colorless anodized or colorless chromated
  • Material: aluminum, extruded Finish: colorless chromated
  • Material: aluminum, extruded Finish: colorless chromated
  • Side Panel RFI without flange Material: aluminum, 2.5 mm thick Finish: blank, seawater resistant
  • For easy screwless snap-on mounting of connectors accordance to IEC 60 603/ DIN 41 612. With a provision for a spring to contact front panels and for contacting a track near the PCB edge. This snap-in card guides can als be secured with screws.
  • Card Guide with integrated push and pull assist This special card guide with an integral small lever aids in the handling of PCB’s with high pin plug in connectors. The lever is supported by the walls of a special guide chamber when the board is pulled out or pushed in. It is suitable for a spring to contact a track near the PCB edge. This card guides are snapin and can be secured with screws.
  • 20 HP for horizontal mounting of 6 U PCB‘s in 3 U subracks. The horizontal mounting frame needs 52 HP in the width. For 84 HP subracks are available Placed right: 52 HP for horizontal mounting frame, 32 HP for 3 U PCB‘s Placed left: 52 HP for horizontal mounting frame, 1 HP for air and leakage paths, 31 HP for 3 U PCB‘s.
  • Self adhesive. For identifiying PCB slots in the subrack. The PCB slot number can be read thru the hole in the front panel. Note: The label strip cannot be read while using the RFI spring P2. Material: PC/PE foil Color: yellow/black
  • This hinged labelling rail is mounted on the subrack flanges. Normally it is placed in front of the front panels. For ejecting a PCB, the rail is turned down.
  • For locking of PCB‘s witout front panels. The locking rail is mounted at the horizontal rail in front of the PCB‘s. A labeling strip can be insert into a groove.
  • Mounting Rail B tapped M 2.5 For mounting connectors in accordance to IEC 60 603/ DIN 41 612. For mounting at the rear profile on subracks type alpha with insulating strip and insulating bushings. For mounting at the rear profile on subracks type delta. Material: aluminum Finish: blank
  • Partition Wall For partitioning of a subrack part. The partition wall 6 U can also be used as a RFI shielded subrack divider in 6 U and 2x3 U parts.
  • Secures PCB’s without front panels. Used for easy locking and ejecting of PCB’s
  • Secures PCB without front panels.
  • Separating Wall For separating a subrack int two fields. Material: aluminum Finish: blank Delivery: 1 separating wall Mounting parts
  • Subrack Divider Kit 2 x 3 U - 42 HP and 6 U - 40 HP The divider separates a 6 U subrack into a field for 6 U PCB’s and 2 fields of 3 U. Finish: colorless chromated Delivery: 1 double front profile 2xVE1 43 HP chromated 1 double rear profile 2xHK 43 HP anodized 2 divider strips Assembly: Mounting parts
  • Subrack Divider Kit 2 x 3 U - 84 HP For partitioning a 6 U subrack in 2 x 3 U.
  • Threaded Strip M 2.5 For attaching the front panels and assembly parts at the wiring field. Material: steel Finish: galvanized, chromated
  • Threaded Strip M 2.5 - stainless steel For attaching the front panels and assembly parts at the wiring field. This threaded strip is for nonmagnetic applications. Material: stainless steel Finish: blank
  • Threaded Strip M 2.5 addable This threaded strip could be added to other strips and the space between the holes always adds up 5.08 mm. Material: steel Finish: galvanized, chromated
  • Threaded Strip M 3 Material: steel Finish: galvanized, chromated
  • Threaded Strip M 3 addable Material: steel Finish: galvanized, chromated
  • Z-Rail A tapped M 2.5 For mounting connectors in accordance to IEC 60 603/ DIN 41 612 in subracks type alpha. Mounted on the rear profile. Material: aluminum Finish: colorless chromated
  • For covering empty sections or to carry various components in subracks. Four versions are available: 1. Flat front panel blank The front side is covered with a removable transparent foil. 2. Flat front panel anodized Front anodized, rear conductive. 3. Flat front panel RFI Front anodized, rear conductive, with slits in the side edges for insertion of RFI springs. 4. Extruded front panel RFI Made of extruded aluminum alloy, with slits in the side edges for insertion of RFI springs for contact. Surface finish is colorless chromated.
  • Blind Front Panels RFI Finish: flat front panel: front side anodized, rear side conductive extruded front panel: colorless chromated
  • Blind Front Panels RFI Finish: flat front panel: front side anodized, rear side conductive extruded front panel: colorless chromated
  • Finish: Flat front panel: front side anodized, rear side conductive Extruded front panel: colorless chromated
  • Ejector Handle The ejector handle extends through the front panel and is screwed together with the bearing bushing at the front connector.
  • Front Panels with IEEE Handle For easy pull of PCB’s with high density connectors accordance specification IEEE 1101.10. The assambled handle kit is stuck in the milled space of the front panel and is secured with a clamped spring. Afterwards the PCB are screwed on the intergrated front connector. Two versions with IEEE handle are available: 1. Flat front panel RFI Front anodized, rear conductive. With slits in the side edges for insertion of RFI springs. 2. Extruded front panel RFI Made of extruded aluminum alloy, with slits in the side edges for insertion of RFI springs or for contacting. Surface finish is colorless chromated.
  • Front Panels with Ejector Handle For easy release of PCB’s with high pin connections. The ejector handle is extends through the front panel and is screwed together with the bearing bushing at the front connector. Four versions are available: 1. Flat front panel blank. The front side is covered with a removable transparent foil. 2. Flat front panel anodized. Front anodized, rear conductive. 3. Flat front panel RFI Front anodized, rear conductive. With slits in the side edges for insertion of RFI springs. 4. Extruded front panel RFI Made of extruded aluminum alloy, with slits in the side edges for insertion of RFI springs for contact. Surface finish is colorless chromated.
  • For assembly on a PCB. Handle and front connector are screwed on the front panel. The plain front panel is easy to modify. Four versions are available: 1. Flat front panel blank The front side is covered with a removable transparent foil. 2. Flat front panel anodized Front anodized, rear conductive. 3. Flat front panel RFI Front anodized, rear conductive. With slits in the side edges for insertion of RFI springs. 4. Extruded front panel RFI Made of extruded aluminum alloy, with slits in the side edges for insertion of RFI springs for contact. Surface finish is colorless chromated.
  • Handle FP Assembled with M 2.5 screws and with 1 additional self tapping screw from 6 HP. The handle is held against torsion by means of two nipples.
  • Hinged Front Panel 85 HP With slits in the side edges for insertion of RFI springs. The hinge is screwed to the profiled rail of the subrack. An 84 HP threaded strip is needed. To be used in combination with below mentioned flanges only. Finish: front side anodized, rear side conductive Delivery: 1 front panel 1 hinge 3 grounding bushings Mounting parts Delivery: as unassembled kit. Assembled kits on request.
  • Ident Plate for handle FP. The ident plate is markable and printable, snapped in after mounting the handle to the front panel.