• Cover Plate Fs, slide-in Hole diameter 8.5 mm. The cover plate slides in special slots in the profiles. Material: aluminum, 1.5 mm thick Finish: blank, seawater resistant
  • Ejector Handle The ejector handle extends through the front panel and is screwed together with the bearing bushing at the front connector.
  • The flange can be mounted to the side panel by means of the mounting screws for the horizontal rails. Material: aluminum, extruded Finish: anodized
  • Flange for Wall Mounting For mounting of a subrack on a wall. Material: aluminum Finish: blank, seawater resistant
  • This flange is suitable for mounting of a continous front panel of 85 HP and a hinged front panel of 85 HP in a subrack. The flange will be mounted to the side panel by means of the mounting screws for the horizontal rails. Material: aluminum, extruded Finish: colorless chromated
  • Flange without Nose This flange can be mounted at various depth on the side panel grid. Material: aluminum, extruded Finish: anodized
  • Front Panels with IEEE Handle For easy pull of PCB’s with high density connectors accordance specification IEEE 1101.10. The assambled handle kit is stuck in the milled space of the front panel and is secured with a clamped spring. Afterwards the PCB are screwed on the intergrated front connector. Two versions with IEEE handle are available: 1. Flat front panel RFI Front anodized, rear conductive. With slits in the side edges for insertion of RFI springs. 2. Extruded front panel RFI Made of extruded aluminum alloy, with slits in the side edges for insertion of RFI springs or for contacting. Surface finish is colorless chromated.
  • Front Panels with Ejector Handle For easy release of PCB’s with high pin connections. The ejector handle is extends through the front panel and is screwed together with the bearing bushing at the front connector. Four versions are available: 1. Flat front panel blank. The front side is covered with a removable transparent foil. 2. Flat front panel anodized. Front anodized, rear conductive. 3. Flat front panel RFI Front anodized, rear conductive. With slits in the side edges for insertion of RFI springs. 4. Extruded front panel RFI Made of extruded aluminum alloy, with slits in the side edges for insertion of RFI springs for contact. Surface finish is colorless chromated.
  • For assembly on a PCB. Handle and front connector are screwed on the front panel. The plain front panel is easy to modify. Four versions are available: 1. Flat front panel blank The front side is covered with a removable transparent foil. 2. Flat front panel anodized Front anodized, rear conductive. 3. Flat front panel RFI Front anodized, rear conductive. With slits in the side edges for insertion of RFI springs. 4. Extruded front panel RFI Made of extruded aluminum alloy, with slits in the side edges for insertion of RFI springs for contact. Surface finish is colorless chromated.
  • Front Profile VE1 (also rear profile by using of a front panel on the rear). Material: aluminum Finish: anodized
  • Material: aluminum Finish: anodized
  • Handle FP Assembled with M 2.5 screws and with 1 additional self tapping screw from 6 HP. The handle is held against torsion by means of two nipples.
  • Hinged Front Panel 85 HP With slits in the side edges for insertion of RFI springs. The hinge is screwed to the profiled rail of the subrack. An 84 HP threaded strip is needed. To be used in combination with below mentioned flanges only. Finish: front side anodized, rear side conductive Delivery: 1 front panel 1 hinge 3 grounding bushings Mounting parts Delivery: as unassembled kit. Assembled kits on request.
  • 20 HP for horizontal mounting of 6 U PCB‘s in 3 U subracks. The horizontal mounting frame needs 52 HP in the width. For 84 HP subracks are available Placed right: 52 HP for horizontal mounting frame, 32 HP for 3 U PCB‘s Placed left: 52 HP for horizontal mounting frame, 1 HP for air and leakage paths, 31 HP for 3 U PCB‘s.
  • Ident Plate for handle FP. The ident plate is markable and printable, snapped in after mounting the handle to the front panel.
  • Ident-plate 4 HP The ident-plate is markable and printable. Snapped in after mounting the handle at the front panel. Material: aluminum Finish: silver silk matt anodized
  • Insulating Strip For insulated mounting of wiring supports, e. g. of the mounting rail B. Mounted between horizontal rail and wiring support.
  • Self adhesive. For identifiying PCB slots in the subrack. The PCB slot number can be read thru the hole in the front panel. Note: The label strip cannot be read while using the RFI spring P2. Material: PC/PE foil Color: yellow/black
  • This hinged labelling rail is mounted on the subrack flanges. Normally it is placed in front of the front panels. For ejecting a PCB, the rail is turned down.
  • For locking of PCB‘s witout front panels. The locking rail is mounted at the horizontal rail in front of the PCB‘s. A labeling strip can be insert into a groove.
  • Mounting Rail B tapped M 2.5 For mounting connectors in accordance to IEC 60 603/ DIN 41 612. For mounting at the rear profile on subracks type alpha with insulating strip and insulating bushings. For mounting at the rear profile on subracks type delta. Material: aluminum Finish: blank
  • Partition Wall For partitioning of a subrack part. The partition wall 6 U can also be used as a RFI shielded subrack divider in 6 U and 2x3 U parts.
  • Secures PCB’s without front panels. Used for easy locking and ejecting of PCB’s
  • Secures PCB without front panels.